173 research outputs found

    The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults

    Get PDF
    Purpose Changes in retinal thickness are common in various ocular diseases. Transverse magnification due to differing ocular biometrics, in particular axial length, affects measurement of retinal thickness in different regions. This study evaluated the effect of axial length and refractive error on measured macular thickness in two community-based cohorts of healthy young adults. Methods A total of 2160 eyes of 1247 community-based participants (18–30 years; 23.4% myopes, mean axial length = 23.6mm) were included in this analysis. Macular thickness measurements were obtained using a spectral-domain optical coherence tomography (which assumes an axial length of 24.385mm). Using a custom program, retinal thickness data were extracted at the 9 Early Treatment of Diabetic Retinopathy Study (ETDRS) regions with and without correction for transverse magnificent effects, with the corrected measurements adjusting according to the participant’s axial length. Linear mixed models were used to analyse the effect of correction and its interaction with axial length or refractive group on retinal thickness. Results The raw measures (uncorrected for axial length) underestimated the true retinal thickness at the central macula, while overestimating at most non-central macular regions. There was an axial length by correction interaction effect in all but the nasal regions (all p\u3c0.05). For each 1mm increase in axial length, the central macular thickness is overestimated by 2.7–2.9μm while thicknesses at other regions were underestimated by 0.2–4.1μm. Based on the raw thickness measurements, myopes have thinner retinas than non-myopes at most non-central macular. However, this difference was no longer significant when the corrected data was used. Conclusion In a community-based sample, the raw measurements underestimate the retinal thickness at the central macula and overestimate the retinal thickness at non-central regions of the ETDRS grid. The effect of axial length and refractive error on retinal thickness is reduced after correcting for transverse magnification effects resulting from axial length differences

    Influence of the time of day on axial length and choroidal thickness changes to hyperopic and myopic defocus in human eyes

    Get PDF
    © 2019 Elsevier Ltd. This manuscript version is made available under the CC-BY-NC-ND 4.0 license: http://creativecommons.org/licenses/by-nc-nd/4.0/ This author accepted manuscript is made available following 12 month embargo from date of publication (March 2019) in accordance with the publisher’s archiving policyResearch in animal models have shown that exposing the eye to positive or negative spectacle lenses can lead to predictable changes in eye growth. Recent research indicates that brief periods (1–2 h) of monocular defocus results in small, but significant changes in axial length and choroidal thickness of human subjects. However, the effects of the time of day on these ocular changes with defocus are not known. In this study, we examined the effects of monocular myopic and hyperopic defocus on axial length and choroidal thickness when applied in the morning (change between 10 a.m. and 12 p.m.) vs the evening (change between 5 and 7 p.m.) in young adult human participants (mean age, 23.44 ± 4.52 years). A series of axial length (using an IOL Master) and choroidal thickness (using an optical coherence tomographer) measurements were obtained over three consecutive days in both eyes. Day 1 (no defocus) examined the baseline ocular measurements in the morning (10 a.m. and 12 p.m.) and in the evening (5 and 7 p.m.), day 2 investigated the effects of hyperopic and myopic defocus on ocular parameters in the morning (subjects wore a spectacle lens with +3 or −3 DS over the right eye and a plano lens over the left eye between 10 a.m. and 12 p.m.), and day 3 examined the effects of defocus in the evening (+3 or −3 DS spectacle lens over the right eye between 5 and 7 p.m.). Exposure to myopic defocus caused a significant reduction in axial length and thickening of the subfoveal choroid at both times; but, compared to baseline data from day 1, the relative change in axial length (−0.021 ± 0.009 vs +0.004 ± 0.003 mm, p = 0.009) and choroidal thickness (+0.027 ± 0.006 vs +0.007 ± 0.006 mm, p = 0.011) with defocus were significantly greater for evening exposure to defocus than for the morning session. On the contrary, introduction of hyperopic defocus resulted in a significant increase in axial length when given in the morning (+0.026 ± 0.006 mm), but not in the evening (+0.001 ± 0.003 mm) (p = 0.047). Furthermore, hyperopic defocus resulted in a significant thinning of the choroid (p = 0.005), but there was no significant influence of the time of day on choroidal changes associated with hyperopic defocus (p = 0.672). Exposure to hyperopic and myopic defocus at different times of the day was also associated with changes in the parafoveal regions of the choroid (measured across 1.5 mm nasal and temporal choroidal regions on either side of the fovea). Our results show that ocular response to optical defocus varies significantly depending on the time of day in human subjects. These findings represent a potential interaction between the signal associated with the eye's natural diurnal rhythm and the visual signal associated with the optical defocus, making the eye perhaps more responsive to hyperopic defocus (or ‘go’ signal) in the morning, and to myopic defocus (or ‘stop’ signal) in the latter half of the day

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.Peer reviewe

    Non-invasive assessment of tear film surface quality

    Get PDF
    The tear film plays an important role preserving the health of the ocular surface and maintaining the optimal refractive power of the cornea. Moreover dry eye syndrome is one of the most commonly reported eye health problems. This syndrome is caused by abnormalities in the properties of the tear film. Current clinical tools to assess the tear film properties have shown certain limitations. The traditional invasive methods for the assessment of tear film quality, which are used by most clinicians, have been criticized for the lack of reliability and/or repeatability. A range of non-invasive methods of tear assessment have been investigated, but also present limitations. Hence no “gold standard” test is currently available to assess the tear film integrity. Therefore, improving techniques for the assessment of the tear film quality is of clinical significance and the main motivation for the work described in this thesis. In this study the tear film surface quality (TFSQ) changes were investigated by means of high-speed videokeratoscopy (HSV). In this technique, a set of concentric rings formed in an illuminated cone or a bowl is projected on the anterior cornea and their reflection from the ocular surface imaged on a charge-coupled device (CCD). The reflection of the light is produced in the outer most layer of the cornea, the tear film. Hence, when the tear film is smooth the reflected image presents a well structure pattern. In contrast, when the tear film surface presents irregularities, the pattern also becomes irregular due to the light scatter and deviation of the reflected light. The videokeratoscope provides an estimate of the corneal topography associated with each Placido disk image. Topographical estimates, which have been used in the past to quantify tear film changes, may not always be suitable for the evaluation of all the dynamic phases of the tear film. However the Placido disk image itself, which contains the reflected pattern, may be more appropriate to assess the tear film dynamics. A set of novel routines have been purposely developed to quantify the changes of the reflected pattern and to extract a time series estimate of the TFSQ from the video recording. The routine extracts from each frame of the video recording a maximized area of analysis. In this area a metric of the TFSQ is calculated. Initially two metrics based on the Gabor filter and Gaussian gradient-based techniques, were used to quantify the consistency of the pattern’s local orientation as a metric of TFSQ. These metrics have helped to demonstrate the applicability of HSV to assess the tear film, and the influence of contact lens wear on TFSQ. The results suggest that the dynamic-area analysis method of HSV was able to distinguish and quantify the subtle, but systematic degradation of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions. Thus, the HSV method appears to be a useful technique for quantitatively investigating the effects of contact lens wear on the TFSQ. Subsequently a larger clinical study was conducted to perform a comparison between HSV and two other non-invasive techniques, lateral shearing interferometry (LSI) and dynamic wavefront sensing (DWS). Of these non-invasive techniques, the HSV appeared to be the most precise method for measuring TFSQ, by virtue of its lower coefficient of variation. While the LSI appears to be the most sensitive method for analyzing the tear build-up time (TBUT). The capability of each of the non-invasive methods to discriminate dry eye from normal subjects was also investigated. The receiver operating characteristic (ROC) curves were calculated to assess the ability of each method to predict dry eye syndrome. The LSI technique gave the best results under both natural blinking conditions and in suppressed blinking conditions, which was closely followed by HSV. The DWS did not perform as well as LSI or HSV. The main limitation of the HSV technique, which was identified during the former clinical study, was the lack of the sensitivity to quantify the build-up/formation phase of the tear film cycle. For that reason an extra metric based on image transformation and block processing was proposed. In this metric, the area of analysis was transformed from Cartesian to Polar coordinates, converting the concentric circles pattern into a quasi-straight lines image in which a block statistics value was extracted. This metric has shown better sensitivity under low pattern disturbance as well as has improved the performance of the ROC curves. Additionally a theoretical study, based on ray-tracing techniques and topographical models of the tear film, was proposed to fully comprehend the HSV measurement and the instrument’s potential limitations. Of special interested was the assessment of the instrument’s sensitivity under subtle topographic changes. The theoretical simulations have helped to provide some understanding on the tear film dynamics, for instance the model extracted for the build-up phase has helped to provide some insight into the dynamics during this initial phase. Finally some aspects of the mathematical modeling of TFSQ time series have been reported in this thesis. Over the years, different functions have been used to model the time series as well as to extract the key clinical parameters (i.e., timing). Unfortunately those techniques to model the tear film time series do not simultaneously consider the underlying physiological mechanism and the parameter extraction methods. A set of guidelines are proposed to meet both criteria. Special attention was given to a commonly used fit, the polynomial function, and considerations to select the appropriate model order to ensure the true derivative of the signal is accurately represented. The work described in this thesis has shown the potential of using high-speed videokeratoscopy to assess tear film surface quality. A set of novel image and signal processing techniques have been proposed to quantify different aspects of the tear film assessment, analysis and modeling. The dynamic-area HSV has shown good performance in a broad range of conditions (i.e., contact lens, normal and dry eye subjects). As a result, this technique could be a useful clinical tool to assess tear film surface quality in the future

    Computationally efficient interference detection in videokeratoscopy images

    Get PDF
    Abstract—An optimal videokeratoscopic image presents a strong well-oriented pattern over the majority of the measured corneal surface. In the presence of interference, arising from reflections from eyelashes or tear film instability, the pattern's flow is disturbed and the local orientation of the area of interference is no longer coherent with the global flow. Detecting and analysing videokeratoscopic pattern interference is important when assessing tear film surface quality, break-up time and location as well as designing tools that provide a more accurate static measurement of corneal topography. In this paper a set of algorithms for detecting interference patterns in videokeratoscopic images is presented. First a frequency approach is used to subtract the background information from the oriented structure and then a gradient-based analysis is used to obtain the pattern's orientation and coherence. The proposed techniques are compared to a previously reported method based on statistical block normalisation and Gabor filtering. The results indicate that the proposed technique leads, in most cases: to a better videokeratoscopic interference detection system, that for a given probability of the useful signal detection (99.7%) has a significantly lower probability of false alarm, and at the same time is computationally much more efficient than the previously reported method

    Assessment of tear film surface quality using dynamic-area high-speed videokeratoscopy

    Get PDF
    A new method for noninvasive assessment of tear film surface quality (TFSQ) is proposed. The method is based on high-speed videokeratoscopy in which the corneal area for the analysis is dynamically estimated in a manner that removes videokeratoscopy interference from the shadows of eyelashes but not that related to the poor quality of the precorneal tear film that is of interest. The separation between the two types of seemingly similar videokeratoscopy interference is achieved by region-based classification in which the overall noise is first separated from the useful signal (unaltered videokeratoscopy pattern), followed by a dedicated interference classification algorithm that distinguishes between the two considered interferences. The proposed technique provides a much wider corneal area for the analysis of TFSQ than the previously reported techniques. A preliminary study with the proposed technique, carried out for a range of anterior eye conditions, showed an effective behavior in terms of noise to signal separation, interference classification, as well as consistent TFSQ results. Subsequently, the method proved to be able to not only discriminate between the bare eye and the lens on eye conditions but also to have the potential to discriminate between the two types of contact lenses

    Speckle reduction in optical coherence tomography imaging by affine-motion image registration

    Get PDF
    Signal-degrading speckle is one factor that can reduce the quality of optical coherence tomography images. We demonstrate the use of a hierarchical model-based motion estimation processing scheme based on an affine-motion model to reduce speckle in optical coherence tomography imaging, by image registration and the averaging of multiple B-scans. The proposed technique is evaluated against other methods available in the literature. The results from a set of retinal images show the benefit of the proposed technique, which provides an improvement in signal-to-noise ratio of the square root of the number of averaged images, leading to clearer visual information in the averaged image. The benefits of the proposed technique are also explored in the case of ocular anterior segment imaging

    Estimating corneal surface topography in videokeratoscopy in the presence of strong signal interference

    Get PDF
    Videokeratoscopy techniques rely on a number of factors in order to achieve accurate estimates of corneal surface topography. Good tear film quality, minimal reflections from eyelashes, and minimal eye movements are essential for corneal topography estimates to be reliable. However, in practice, these ideal conditions may not always be fulfilled, especially in cases of subjects diagnosed with dry eye syndrome, having narrow palpebral apertures, long eyelashes, or nystagmus (uncontrolled eye movements). Such nonoptimal conditions of image acquisition result in poorer estimates of corneal topography. The aim of this paper was to devise a technique that would provide more accurate estimation of corneal topography in such situations and particularly when the source of signal interference is strong. This was achieved by developing a set of algorithms that extract the interference from the acquired raw videokeratoscopic image and filter the topography according to the interference location. The experiments carried out with test surfaces and real corneas showed that this new technique leads to a significant improvement in the topography estimator. Additionally, it is an interference indication procedure that, in the future, could be used for the purpose of tear film quality estimation

    Noninvasive in vivo assessment of soft contact lens type on tear film surface quality

    Get PDF
    This article is free to read on the publisher's website To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types

    Tear film surface quality with rigid and soft contact lenses

    Get PDF
    Objectives: To measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hours) use of rigid and soft contact lenses. Methods: A group of fourteen subjects wore 3 different types of contact lenses on 3 different non-consecutive days (order randomized) in one eye only. Subjects were screened to exclude those with dry eye. The lenses included a PMMA hard, an RGP (Boston XO) and a soft silicone hydrogel lens. Three 30 second long high speed videokeratoscopy recordings were taken with contact lenses in-situ, in the morning and again after 8 hours of contact lens wear, both in normal and suppressed blinking conditions. Recordings were also made on a baseline day with no contact lens wear. Results: The presence of a contact lens in the eye had a significant effect on the mean TFSQ in both natural and suppressed blinking conditions (p=0.001 and p=0.01 respectively, repeated measures ANOVA). TFSQ was worse with all the lenses compared to no lens in the eye (in the afternoon during both normal and suppressed blinking conditions (all p<0.05). In natural blinking conditions, the mean TFSQ for the PMMA and RGP lenses was significantly worse than the baseline day (no lens) for both morning and afternoon measures (p<0.05). Conclusions: This study shows that both rigid and soft contact lenses adversely affect the TFSQ in both natural and suppressed blinking conditions. No significant differences were found between the lens types and materials. Keywords: Tear film surface quality, rigid contact lens, soft contact lens, dynamic high-speed videokeratoscop